Alternative
Wastewater Treatment Design for Escuela Litoral
(resumens de
los informes en Espaņol
(PDF)
International Senior Design – Santa Cruz, Bolivia –
Summer 2005
JMP
Engineering
Jennifer Heglund, Megan Ross,
& Parker Sovey
|
|
Escuela Litoral
is located between the 5th and 6th rings of the city of Santa Cruz,
Bolivia. 1500 students attend classes in two equal shifts throughout
the day. The current septic system is undersized and requires frequent
cleaning & pumping. The government supplies funds for pumping
once a year, so two women frequently clean the tank by hand. To keep
the flow to the system as low as possible, the toilets in the restrooms
are flushed only twice per day. Since the system is frequently at
capacity, excess waste seeps out of the septic tank and dry well and
flows up the soil to the surface. Children play in contaminated soil
at recess and there are many cases of illness.
|
|
Site
Investigation
Drinking water quality
Site survey
Soil borings
Wastewater flow determination
Health hazard inquiry
|
|
|
|
|
|
Site
Conditions
Satisfactory drinking water
Limited construction area
Clay soils (low permeability)
High wastewater flow
Biologically contaminated soils
|
|
|
|
|

|
Alternatives

|

|
Interim
Design
Modified Galeria Filtrante with Low Flow Toilets
1 septic tank
54-hr detention time
Dispersal over 7 days
Decrease daily flow by 25%
Dimensions: 9.7 x 2.7 x 2.25 m
3 modified galeria filtrantes
Modified from Bolivian design
Filled with sand instead of lined with bricks
Less expensive & more treatment
Depth: 4 m
2 sizes:
1 – 4 m diameter
2 – 4.5 m diameter
Each with three 8 m long trenches
Located in low traffic areas with adequate space
Estimated construction time: approx. 19 work days |
|
 |
 |
Final
Recommendations
Current system is failing due to its small size, poor soils, &
large flow
Design of a new system is constrained by large flow, poor soils, &
limited space
Interim Design – Modified Galeria Filtrante has an estimated
lifetime 10 years
Less expensive to keep current system, but extremely hazardous to
the health of the children
Only permanent solution is a sanitary sewer & wastewater treatment
plant for the community
|
|
|
|
Michigan Technological
University
Department of Civil and Environmental Engineering
1400 Townsend Drive
Houghton, Michigan, 49931 - 1295, USA
Department Phone: 1-906-487-2520
Department Fax: 1-906-487-2943
Department E-mail: cee@mtu.edu
© 2005 Michigan Technological University
The sale or commercial use of Illustrations, photographs and graphic images
presented on this site is not permitted. Educational uses are permitted,
provided credit is given to sources.
|
|