Figure 2< |
|
THE PLAN
- Design a Complete Septic
System for a
Future School of 500 Students
-
Include Local Building Practices
in the Design
- Secure Funding, Materials
and Labor
- Build the Septic Tank,
Sedimentation
Basin and Adsorption Field
|

Figure 3 |
|
THE DESIGN
Three Steps to Clean Waste
1. Two Chamber Septic Tank
2. Sedimentation Basin
3. Adsorption Field
|

Figure 4 |
|
SEPTIC
TANK DESIGN
Two
compartment tank provides better
suspended solids removal
2.2 Gallons H20/student/day
Detention Time = 48 hrs
Tank Volume = 2,200 gal = 294 ft3
Tank Dimensions = 6’ x 13’ x 4’
|
|
|
SEDIMENTATION
BASIN
Volume = 740 ft3
Dimensions:
Diameter= 6.5 ft
Height = 7 ft
|
Slide
Show Scenes of 2003 Projects |
|
ADSORPTION
FIELD
Percolation rate = 4.5 min/in
of fall
Max rate of sewer application
= 2.42 gal/ft2/day
Expected flow = 1,100 gal/day
Area for adsorption = 460 ft2
Trench Length = 170 ft
|
|